(b) Disconnect the instrument panel wire from the spiral cable.
(c) Check for a short to B+ in the circuit.
(1) Connect the cable to the negative (-) battery terminal.
(2) Turn the ignition switch to ON.
(3) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
(d) Check for an open in the circuit.
(1) Turn the ignition switch off.
(2) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(3) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(e) Check for a short to ground in the circuit.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(f) Check for a short in the circuit.
(1) Release the activation prevention mechanism built into connector B See: Restraints and Safety Systems/Air Bag Systems/Testing
and Inspection/Initial Inspection and Diagnostic Overview/Diagnosis System.
(2) Measure the resistance according to the value(s) in the table below.