3. CHECK NO. 2 FLOOR WIRE (SHORT TO B+)
(a) Disconnect SST from connector C.
(b) Connect the cable to the negative (-) battery terminal.
(c) Turn the ignition switch to ON.
(d) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
NG -- REPLACE NO. 2 FLOOR WIRE
OK -- Continue to next step.
4. CHECK NO. 2 FLOOR WIRE (SHORT TO GROUND)
(a) Turn the ignition switch off.
(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(c) Measure the resistance according to the value(s) in the table below.